Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM04266
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/15/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM04266 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Proposed suspended ceiling in this project is of "wood" material which is heavier in weight than the conventional light weight gypsum ceiling tiles. Details shown for suspended ceiling are meant as prescriptive details for light-weight ceilings, so please provide structural design for the proposed wood suspended ceiling framing and suspended brace system. 2. Architectural drawings shows new "curtain wall" system, please provide design for the proposed curtain wall system. 3. Structural calculation page provided for review states that no new lateral loads are imposed as one of the existing exterior wall is moved out to form the enclosure's new exterior wall. Agreed but, the details for the braced panels in the new exterior wall still needs to be calculated and their details shown on the plan. Please provide the details along-with the supporting calcs. 4. Seems like the foundation design for the new foundations is not provided, please provide these details and calcs. BUILDING REVIEW COMMENTS: Denied 1. The occupancy class listed is incorrect. The sales floor would be a mercantile occupancy. Provide a corrected occupancy class and correlate all applicable requirements. 2. There are sheets that have different areas on them. Ensure all sheets correlate properly. 3. Sheet A0.0: The occupant load calculation for the sales area is incorrect. See previous comment regarding occupancy classification. Provide a corrected occupant load calculation. 4. Provide a complete list of special inspections as required by Ch. 17. MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 06/27/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 07/01/2022 | SSHIELD1 | ENGINEERING | REVIEW | Reqs Change | See Zoning commnets |
| 07/01/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM04266 – DP22-0012 831 W Wetmore Rd – C-2 Vehicle Rental and Sales (1st Review) TRANSMITTAL: July 1, 2022 This site is located in C-2 Zone (UDC 4.7.21), Vehicle Rental and Sales is an use is an allowed use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.9.G.1& .2. 1. Zoning has reviewed this building plan for compliance with DP22-0012 and although it appears to be in compliance until the DP is approved Zoning cannot approve this plan. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 07/01/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 07/18/2022 | JPEELDA1 | FIRE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/18/2022 | VVERA1 | OUT TO CUSTOMER | Completed |