Permit Number: T22CM04254
Parcel: 136402940

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM04254
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2022 GPENNIN1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Georgia Pennington
Planner

PROJECT: T22CM04254
10022 E Amanda Paige Drive
(Patio) (1st Review)

TRANSMITTAL DATE: (4/26/22)

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. Provide a complete plot plan that includes all the requirements. It appears you are missing some elements. Use this link for guidance: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

2. Provide setback dimensions from the patio to all property lines. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure facing each interior property line (Table 6.3-2.A).

Based on a height of 7'7", the required perimeter yard setback to the south property line is 6'. It does not appear the patio meets this requirement. If it does not, a Design Development Option (DDO) must be submitted and approved to reduce the required setback.

A Design Development Option (DDO) must be submitted and approved to reduce the required setbacks. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type "Zoning Administration".
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type "Zoning Administration". If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov.
07/05/2022 SSHIELD1 ENGINEERING REVIEW Passed
07/12/2022 AWARNER1 NPPO REVIEW Approved
07/15/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed .