Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM04245
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/17/2022 | WBERGER1 | ZONING | REVIEW | Approved | |
| 06/17/2022 | WBERGER1 | ENGINEERING | REVIEW | Passed | |
| 06/17/2022 | WBERGER1 | NPPO | REVIEW | Passed | |
| 06/27/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM04245 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved Existing structure to remain. BUILDING REVIEW COMMENTS: Denied 1. Provide dimensions on the drawings for the new wall locations. The graph paper appears to be one square equal one foot however there is no wall widths shown and it is difficult to determine actual sizes of the rooms and plumbing fixture clearances. 2. Indicate the exact location of the new doorway from the existing living room to the new Lounge area including the door size. 3. Note on the drawings that fire blocking will be installed in all walls and concealed spaces prior to covering. 2018 IRC R302.11. 4. Indicate the type of window and/or clear opening for the new bedroom and verify that it will meet egress requirements per 2018 IRC 310 for both size and height off of finished floor. 5. Correct the note on sheet 2 Converted Covered Carport Note #9 that indicates the new walls will be R-30. The new walls are required to have a minimum of R13, and the ceiling is R30. 6. Indicate a new stoop or landing including the material type (wood concrete) outside of the new Lounge Area sliding doors. The stoop or landing must be a minimum of 36” in the direction of travel and as wide as the opening portion of the door. 2018 R311.3. MECHANICAL REVIEW COMMENTS: Denied 1. Indicate a bath fan in the new bathroom or provide a window in this room. 2018 IRC R303.3. Note on the drawings that all bath fans will be exhausted directly to the exterior. 2018 IRC M1505.2. ELECTRICAL REVIEW COMMENTS Denied 1. Indicate a new switched light outside of the new sliding glass doors in the Lounge Area that is in compliance with the Pima County exterior lighting requirements. 2017 NEC 210.70. 2. Provide a switch to control a light or switched outlet from the existing living room to the new lounge area. 3. Indicate the location of an existing exterior outlet that is within 25’ of the new mini split units for the servicing of the unit or indicate a new outlets will be provided. 2017 NEC 210.63. 4. Correct electrical plan notes #8 on sheet 3. Note that a minimum of 90% of all lighting fixtures in the dwelling will contain high-efficacy lamps. 2018 IECC R404.1. 5. Indicate the location of the smoke detectors for the entire house including the existing area. Smoke detectors shall be installed in each sleeping room, outside of each sleeping room in the immediate vicinity of the bedroom. 2018 IRC R314.2. Note on the drawings that all smoke detectors shall be hard wired with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. 6. Indicate the location of carbon monoxide detectors. Carbon monoxide detectors shall be installed outside of each sleeping area in the immediate vicinity of the bedrooms. 2018 IRC R315.3. Note on the drawings that carbon monoxide devices shall be hard wired with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined. PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |