Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM04134
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/13/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits ROOF STRUCTURAL PLAN: Locate and size beams, rafters, and headers for supporting live and dead structural loads, R804 or provide an engineer’s calculation, design and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. SECTIONS - DETAILS: Show a complete cross-section detail of the new exterior wall, R106.1.1. Show the minimum 12" x 12" continuous #4 rebar reinforced footing, R403.1. Show exterior wood siding, sheathing and wall framing anchored with ½" x 10" bolts and with pressure treated sill. Show exterior wood siding, sheathing and wall framing with a 6" clearance above the ground, R317.1 item 5. The framed wall may require a stem for achieving the 6" clearance between framing and ground (R317.1 item 5) or the floor level could be raised a minimum of 6" above grade. |
| 07/15/2022 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T22CM04134 9099 S Atterbury Wash Wy Storage shed (2nd Review) TRANSMITTAL DATE: July 15, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. This comment was not addressed. Per UDC 6.6.2.B, an accessory building shall be built only on a lot occupied by a principal building or use. The proposed storage shed is an accessory building and there is currently no principal building or use on the property. A separate permit for a mobile home or other principal building must be applied for and issued prior to issuance of this permit. 2. This comment was not addressed. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. The requirements are listed and numbered within the above provided link. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or 520-837-4951. |
| 07/19/2022 | PCAMARE1 | ENGINEERING | REVIEW | Reqs Change | This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Instructions: • Is this for a new or existing activity application? – Please select New Application. • Submission Type – Select Floodplain Use Permit. • Project Name – Enter a name for your project. • Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided. • Type of Permit – Select Commercial or Residential (Residential is for work on single family residences and duplexes.) • Complete the Applicant Info. • Complete the Contractor, Owner and Architect/Engineer sections as applicable. • Supporting Documentation Upload – Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful. • Sign the application and submit. • You will be given an activity number for your submittal. Please copy and send this number back to us so we can continue the review. |