Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM04103
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/15/2022 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T22CM04103 – Presidio Palms Building Plan Review (1st Review) 1402 W Ajo TRANSMITTAL DATE: 6/15/2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: A Site plan is required for zoning review, show setbacks from porch to nearest mobile home on the site plan on the next submittal. If you have any questions about this transmittal, Contact Iman Monshizadeh at (520) 837-4082 or by email Iman.Monshizadeh@tucsonaz.gov |
| 06/15/2022 | IMONSHI1 | ENGINEERING | REVIEW | Passed | |
| 06/15/2022 | IMONSHI1 | NPPO | REVIEW | Passed | |
| 06/21/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | A wooden porch roof requires a structural design supporting 10 pounds per square foot dead load and 20 psf live. A ledger connection to a mobile dwelling without a load bearing foundation is not code compliant. Update the design with post and beam support adjacent to the mobile. |