Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM04042
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/16/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 06/16/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 06/16/2022 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 06/29/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM04042 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Coordinate the notes for the ceiling insulation, a minimum of R38 is required unless the structure meets the requirements of the exception for R 30 in the 2018 IECC. On sheet A1 the Insulation R Values Table calls for 6” spray foam insulation in the ceiling where as the specifications listed on sheet S1, Division 7 thermal and moisture protection, D insulation, note 3 insulation r values table indicates a 2x8 is to have R 34, 5 ½” spray on closed cell. 2. Note on the plans that fire blocking will be installed in all walls and concealed spaces prior to covering. 2018 IRC R302.11. MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Denied 1. Note that the new can lighting installed in ceiling will be IC rated and sealed for energy efficiency requirements. 2017 NEC 410.66 2. Note that a minimum of 90% of all lighting fixtures in the dwelling will contain high-efficacy lamps. 2018 IECC R404.1. 3. Indicate the location of the smoke detectors for the entire house including the existing area. Smoke detectors shall be installed in each sleeping room, outside of each sleeping room in the immediate vicinity of the bedroom. 2018 IRC R314.2. 4. Modify the smoke detector note on sheet A1 under the standard floor plan notes and remove the sentence that “interconnecting may be required”. All smoke detectors shall be hard wired with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. 5. Indicate the location of carbon monoxide detectors in the entire house including the existing area. Carbon monoxide detectors shall be installed outside of each sleeping area in the immediate vicinity of the bedrooms. 2018 IRC R315.3. Smoke detectors and carbon monoxide alarms may be combined. PLUMBING REVIEW COMMENTS: Denied 1. Correct the plumbing note 10 water conservation on sheet P1 to indicate the max flow for sink faucets and shower heads to be 2.5 gpm, not 3. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |