Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM03995
Parcel: 136061020

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T22CM03995
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/03/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
10/04/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM03995
Addition
2127 S ROBERTO PL Zoning R-1

TRANSMITTAL DATE: October 4, 2022


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


These comments are still applicable


1.COMMENT: For the proposed Sleeping quarters. Since this lot is located on a corner lot, the owner chooses which street lot line is the front lot line. From other than the front lot line , the street perimeter yard is ten feet. The required perimeter yard setback from the proposed sleeping quarters to the west property line is 10’-0”, proposed perimeter yard setback is 3‘7”.The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 10’-9” the required perimeter yard setback from the proposed accessory structure to the south property line is 7’- 3”, the proposed setback is 3’-0”. A Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

2.COMMENT: For the proposed Garage. Since this lot is located on a corner lot, the owner chooses which street lot line is the front lot line . From other than the front lot line , the street perimeter yard is ten feet, the front setback is 20’. The required perimeter yard setback from the proposed garage to the north property line is 20’-0”, proposed perimeter yard setback is 10’-12 ”. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 10’-8” the required perimeter yard setback from the proposed garage to the east property line is 7’ 2”, the proposed setback is 4’-0”. Based on a wall height of 10’-8” the required perimeter yard setback from the proposed garage expansion to the east property line is 7’-2”, the proposed setback is 1’-6”. A Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.


If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov