Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T22CM03812
Parcel: 131010120

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM03812
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/01/2022 JPEELDA1 FIRE REVIEW Approved
06/06/2022 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
06/14/2022 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
06/15/2022 LSHAMIS1 ZONING REVIEW Reqs Change CDRC Transmittal

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: T22CM03812
New PV shade structure
1255 S Beverly Av

TRANSMITTAL DATE: June 15, 2022

DUE DATE: June 16, 2022


1. COMMENT: Zoning has reviewed the building plans for compliance with the associated Development Package DP21-0354. Zoning cannot approve the building plans until the DP is approved.

2. COMMENT: Zoning will review the building plans on the next submittal as it relates to the zoning review purview and compare the building plan footprint, building height, and square footage and location to ensure consistency with the Development Package.

3. COMMENT: Once the plans have been reviewed and approved by PDSD Commercial Plan Reviewers and zoning has verified consistency with the DP, the building plans can be approved by zoning.
06/27/2022 PCAMARE1 ENGINEERING REVIEW Reqs Change See Zoning Comments

Final Status

Task End Date Reviewer's Name Type of Review Description
06/28/2022 VVERA1 OUT TO CUSTOMER Completed