Permit Number: T22CM03793
Parcel: 13419042A

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM03793
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/01/2022 JPEELDA1 FIRE REVIEW Reqs Change Plans show a "Pedestrian Gate" at the Entrance and Exit. Owner shall provide more information regarding gate ie: length, power operated and so on

Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@tucsonaz.gov
520-837-7033
Fire Plans Examiner
06/04/2022 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Passed
06/08/2022 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the electrical plan review comments and provide a written response.
Plans stamped by a Surveyor in 2003 are not valid. Provide as follows and resubmit.
This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered Electrical design professional. Provide complete electrical plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. Ref; 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements
06/15/2022 PCAMARE1 ENGINEERING REVIEW Reqs Change See zoning comments
06/15/2022 PCAMARE1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
06/15/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM03793
Wall
7110 E BROADWAY BL Zoning C-2

TRANSMITTAL DATE: June 15, 2022


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1.COMMENT: Zoning has reviewed the building plan for compliance with DP22-0142 and although it appears that the building plans match the DP Zoning cannot approve the building plans until the DP is approved.

2.COMMENT: It appears that the address is incorrect please provide the correct address.

If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
06/15/2022 VVERA1 OUT TO CUSTOMER Completed