Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM03566
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/11/2022 | GPENNIN1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Georgia Pennington Planner PROJECT: T22CM03566 841 W Virginia St (Patio Awning) (1st Review) TRANSMITTAL DATE: 5/11/22 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. Provide a residential plot plan with all required elements. For a list of requirements, please visit: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf Specifically, the plan is missing the following: A. Lot Coverage calculations including vehicle use area B. Indicate the scale of the plan C. Lot Area D. Square footage of new addition E. A north arrow F. Indicate the maximum structure height If you have any questions about this transmittal, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov. |
| 05/11/2022 | WBERGER1 | ENGINEERING | REVIEW | Passed | |
| 05/11/2022 | WBERGER1 | NPPO | REVIEW | Passed | |
| 06/01/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T22CM03566 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Separate photos from the construction plan .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits GENERAL COMMENTS: 1. Items built without permit may require alteration or improvement for achieving code compliance with the 2018 IRC, R105. Complete construction plans are required for processing a building permit. The plans should show necessary structural changes for achieving building code compliance, 2018 IRC. SITE PLAN: 1. Indicate the location of the patio cover and any utilities supporting or effecting the proposed structure. FOUNDATION PLAN: 1. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1. Show the minimum 12" reinforced footing depth below the undisturbed ground surface R403.1. Show rebar reinforcement with 3" clearance from earth, R403.1.3.5.3. Show a ½" anchor bolts with 7" embedment, R403.1.6. SECTIONS - DETAILS: 1. Show the Post Section Detail with #4 rebar in the footing, R403.1. 2. Show roof (uplift resistance) rafter fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. 3. Show connection at dwelling with fasteners and rafter hangers. Also, show ledger connection (nail or bolt size) to load bearing wall. Please contact the plans reviewer if you have any questions: Ken Van Karsen 520 837-4912 City of Tucson Residential Plan Review |