Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM03432
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/18/2022 | CVASQUE2 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | Second dwelling on parcel requires updating address information with Pima County Addressing to add unit numbers. |
| 08/19/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: PDSD Zoning Review Section PROJECT: T22CM03432 Building Plan Review – R-1 3553 S Victoria Ave (2nd Review) TRANSMITTAL DATE: August 19, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.1 - .9, & .11. 1. Clearly demonstrate that the requirements of UDC Article 4.9.7.B.3, “One dwelling must be at least 25% smaller than the other dwelling”. The square footage is based on gross floor area of both floors. A Board of Adjustment for Variance maybe required. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 08/22/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | 1. The gray water Ordinance #10579/11089 was revised to eliminate a gray drain line from various fixtures which potentially result in insufficient black drainage flow. Remove of the gray drain lines throughout the building with limited connection to the clothes washer and second story bathing fixture. 2. Provide devices rated for application, G2406.3. A diverter valve for waste drainage requires a manufacturer approved listing (provide documentation). Remove the diverter valve or show a complete graywater system with a discharge holding tank, overflow to building drain and backflow valve. |