Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM03416
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM03416 Carport 9321 E PALM TREE DR Zoning R-1 TRANSMITTAL DATE: May 5,2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf This shall in include: a. Zoning of adjacent parcels b. Actual setback dimension. c. All Utility lines d. Property line distances In the link provided below is a Plot plan grid that can be used. https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Grid.pdf 2.COMMENT: Provide an elevation drawing, draw dimension and label the height of the structure measured from design grade to top of wall in order to verify the setbacks. 3.COMMENT: The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). The proposed side street setback for the proposed carport is 9’-0”. At a minimum a Design Development Option (DDO) is required. At this time I am unable to write DDO comments without a wall height for the proposed shed expansion but a DDO will be required. A Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. 4.COMMENT: For the gazebo provide setback dimension and a height. A neighbor’s setback waiver may be used to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property to the south and to the west: My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 05/05/2022 | PCAMARE1 | NPPO | REVIEW | Passed | |
| 05/12/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits Provide a complete plan set showing 2018 IRC compliance including post, beam, rafter and foundation locations and sizing. Any structure placed in the 3-foot fire separation distance from the neighboring property line requires not less than one-hour fire-resistive construction for reducing fire spread across the property line, R302.1. Fire rated materials are found in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. Include plans for the existing shed which also requires fire rated construction. |
| 05/24/2022 | PCAMARE1 | ENGINEERING | REVIEW | Passed |