Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM03408
Parcel: 106031050

Address:
3363 N STONE AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM03408
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM03408
Ramada/Porch
3363 N STONE AV Zoning R-2

TRANSMITTAL DATE: May 4,2022


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. This shall in include:
a. Draw and Label Stone AV

2.COMMENT: Draw dimension and label the height of the structure measured from design grade to top of wall in order to verify the setbacks for the Ramada and porch

3.COMMENT: Per UDC section 6.6.3.E. The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Show how the standard is satisfied. Attach the ramada to the primary structure or A Board of Adjustment for Variance may be required. Board of Adjustment requirements and application can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submittal from the building plan and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. Contact Mark Castro at Mark.Castro@tucsonaz.gov if you have any questions about the Board of Adjustment.
4.COMMENT: Additional comments may be fourth coming.

If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
05/04/2022 PCAMARE1 NPPO REVIEW Passed
05/19/2022 PCAMARE1 ENGINEERING REVIEW Reqs Change This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp.
Instructions:
Is this for a new or existing activity application? – Please select New Application.

Submission Type – Select Floodplain Use Permit.

Project Name – Enter a name for your project.

Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided.

Type of Permit – Select Commercial or Residential (Residential is for work on single family residences and duplexes.)

Complete the Applicant Info.
Complete the Contractor, Owner and Architect/Engineer sections as applicable.

Supporting Documentation Upload – Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful.

Sign the application and submit.

You will be given an activity number for your submittal. Please copy and send this number back to us so we can continue the review.
05/27/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM03408


GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Provide information on the roof structure that indicates the roof sheathing and the finished roofing product on the wall section C on sheet 2 of the plans.
2. Note on the drawings in the design criteria shown on sheet 3 that the structure has been designed to withstand a minimum wind gust of 115 MPH and Seismic Design Category B. 2018 IRC Table R301.2(1) as amended.
3. Note on the drawing on sheet 1 the structural design parameters including the live and dead loads as well as the wind gust and seismic criteria or the new porch.


BUILDING REVIEW COMMENTS:
Denied
1. Provide a section through the bathroom area that shows the bathroom finishes and insulation values for both the walls and the ceilings. The general notes on sheet 2 only reflect the wall finish in the shower area.


MECHANICAL REVIEW COMMENTS:
Denied
1. Clarify if there will be any heating or cooling provided for this space.
2. Indicate on the drawings that the bath fan will be exhausted directly to the exterior (not under the roofed area). 2018 IRC M1505.2.


ELECTRICAL REVIEW COMMENTS
Approved


PLUMBING REVIEW COMMENTS:
Conditionally Approved
1. All plumbing drain, waste and vent systems shall be tested for leaks in accordance with the 2018 IRC P2503.5 prior to concealing.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov