Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM03386
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/27/2022 | CVASQUE2 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | PLEASE CONTACT PC ADDRESSING BUILDING NUMBER NEEDS TO BE ASSIGNED PRIOR TO ISSUANCE Ph# 520-724-9512, EMAIL:ADDRESSING@PIMA.GOV |
| 08/08/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM03386 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved Updated comments after review of the response to earlier comments is provided below: only review items 3 and 4 remains unresolved. 1. Provide a copy of the geotech report mentioned in structural notes on S-drawings.- response acceptable, item resolved. 2. Please have your geotech engineer address foundation drainage issue, whether foundations need to be designed for ground water pressure or not. - response acceptable, item resolved. 3.4 - Removed 5. Weight of masonry wall considered in seismic base shear calculations seems to be low, a value of 66psf is used whereas a value of 80 psf is used normally, please explain. - response acceptable, item resolved. BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Conditionally Approved All corrections complied Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Approved E2.1 Lighting Plan First Floor: Missing Keynote #7 PLUMBING REVIEW COMMENTS: Denied Second Plumbing Review: 1). OK 2). OK 3). OK 4). OK 5). OK -water heater exhaust/intake updated on M2.0 6). OK 7). Same- The initial required high/low drinking fountain can't be substituted, per IPC & ADA, every drinking fountain beyond the minimum can be a dispenser per amendment. -IPC 404.2, 410.3 8). OK 9). OK 10). SAME-Upload complete site utility piping for continuation of water service, sewer & storm as stated on plan pages P1.0 & P1.2 ** didn't find development plan as stated on response narrative** If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 08/09/2022 | SROGERS2 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Reqs Change | |
| 08/09/2022 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: Samuel Rogers, AICP Lead Planner PDSD Zoning Review PROJECT: T22CM03386 - DP22-0117 8300 E Tanque Verde Rd Animal Services - Expansion (2nd Review) TRANSMITTAL: May 20, 2022 This site is located in the SR zone (UDC 4.7.4). Animal Services is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standard 4.9.4.D.5. 1. Zoning has reviewed the building plans for compliance with DP22-0117 and although it appears that the plans match the DP, Zoning cannot verify if all UDC requirements are met until DP22-0117 is approved by zoning. The DP must be approve by zoning before this building permit can be approved. If you have any questions about this transmittal, please contact Samuel Rogers at Samuel.Rogers@tucsonaz.gov |
| 08/15/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Provide documentation that the new building meets the requirements of IFC 2018, Chapter 5, 507.5.1 of 400'. Provide a diagram to TFD from the nearest hydrant to the furthest part of the addition as the hose lays and the distance. If the distance exceeds 400' a fire sprinkler system shall be installed. Second floor appears to be open and possible use for a sleeping area for staff to watch the animals at night (on call room). Please clarify if this is the use. If this is the use it shall be changed from a B to an R Occupancy and meet those separation requirements. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 09/02/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. The DP needs to be approved before the building plans can be approved. 2. This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Instructions: 1. Is this for a new or existing activity application? - Please select New Application. 2. Submission Type - Select Floodplain Use Permit. 3. Project Name - Enter a name for your project. 4. Type of Permit - Select Commercial or Residential (Residential is for work on single family residences and duplexes.) 5. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided. 6. Description of Work - Enter in Floodplain Use Permit for…and then put a description of the work being done or reference the building permit number associated with this floodplain use permit. 7. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account. 8. Complete the Contractor, Owner and Architect/Engineer sections as applicable. 9. Supporting Documentation Upload - Provide a complete cost estimate for the project unless it is for a new build/separate structure. You may also provide additional documents you think will be helpful. 10. Sign the application and submit. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |