Permit Number: T22CM03304
Parcel: 11305193B

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM03304
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/03/2022 IMONSHI1 ZONING REVIEW Reqs Change FROM: Iman Monshizadeh

PDSD Zoning Review Section

PROJECT: T22CM03304 / Carport Addition

Plot Plan Review (1st Review)

2201 E Kleindale / RX-2 Zone

TRANSMITTAL DATE: 05/03/2022



Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.



1.COMMENT: Detached accessory structures cannot be in the front perimeter yard of the property (space between house and front property line. 6.6.3.C Unified Development Code

https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5309



Since this property is a corner lot, the applicant can choose which is considered the front perimeter yard. The west property line can be used as the front perimeter yard, but the storage in the back would have to be relocated to be outside of the full width between the principal structure and the front perimeter yard



2.COMMENT: If proposed structures are relocated on the next submittal. Provide setback dimensions from the structures to the property line. Ensure carport is at least 10’ from the south property line. Setback is measured from the post of the structure to the property line with an allowable 2’ roof overhang.



3.COMMENT: A neighbor waiver will be required for the eastern property line setback. Provide this verbiage signed by the neighbor to the east ON THE SITE PLAN PAGE on the next submittal.



“My Name is ______________ and I am the owner of the property located at ____________. I have reviewed the site plan and I have no objections to structure being located or constructed ______ feet from the property line as depicted on the site plan



Signature:__________________



Date:_______________”



Provide this signed statement ON THE SITE PLAN PAGE in the next submittal.



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
05/03/2022 IMONSHI1 ENGINEERING REVIEW Passed
05/03/2022 IMONSHI1 NPPO REVIEW Passed
05/27/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM03304

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Provide structural calculations for the carport framing members. It is unclear the design parameters that were used for the carport steel support.
2. It appears that the drawings are missing information for the carport. Clarify the rafters or other framing or plywood will be added on top of the steel for the support and attachment of the corrugated roofing.
3. Clarify if the steel structure will be welded or bolted together and provide details for the connections.
4. Indicate the designed live and dead loads for the carport roof structure on the plans and verify the structure has been designed to withstand the wind speed of 115 mph and seismic Category B in accordance with 2018 IRC Table R301.2 (1).


BUILDING REVIEW COMMENTS:
Denied
1. Note on the drawing that all work shall be in accordance with the 2018 IRC and the adopted codes of the City of Tucson.
2. Note on the drawing that the soil beneath the slab and around the footing shall be treated for termites prior to the placement of the concrete for the shed. 2018 IRC R318.


MECHANICAL REVIEW COMMENTS:
Conditionally Approved
No mechanical work has been included with this submittal.


ELECTRICAL REVIEW COMMENTS
Conditionally Approved
No electrical work has been included with this submittal.


PLUMBING REVIEW COMMENTS:
Conditionally Approved
No plumbing work has been included with this submittal.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov