Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM03219
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/30/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Show any outdoor lighting on the proposed property wall with elecrtical circuit location and size. Show full cutoff fixtures were located with 25 feet from the property line OLC 401.3.3. |
| 08/31/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM03219 1914 W Riverview St - R-1 Carport and Storage Addition (2nd Review) TRANSMITTAL: August 31, 2022 This site is located in the R-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 – 9. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall, UDC Article 6.4.5.B & Figure 6.4.5-A. 1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 11’-0” the required perimeter yard setback from the proposed carport/storage addition is 7’-4”, proposed setback is 3’-6”. 2. Per UDC Article 6.6.3.C Detached accessory buildings, including accessory dwelling unit, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. The proposed “WALKING ENTRANCE SHADE 40 SF” is considered an accessory structure and will require a Board of adjustment for Variance to all it as shown on the plan. 3. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height less than 13’-4” the required front street perimeter yard setback from the “WALKING ENTRANCE SHADE 40 SF” to the street property line is 20’-0”, proposed street perimeter yard setback is 0’-0”. The Board of Adjustment can be used to reduce the perimeter yard setback and allow the accessory structure in the front yard therefore only one process would be required. The Board of Adjustment shall be submitted and approved prior to approval of this permit. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submittal from this building plan and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. Contact of the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. The site wall along the street property line with lighting requires a building permit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |