Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM03107
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2022 | SSHIELD1 | ENGINEERING | REVIEW | Reqs Change | See Zoning comments |
| 05/05/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM03107 1346 N Stone Ave Multi-Family (1st Review) TRANSMITTAL: May 5, 2022 This site is located in the OCR-1 zone (UDC 4.7.26). Multi-Family is a permitted use in this zone (Table 4.8-4). 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. |
| 05/05/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 05/09/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM03107 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. In the structural calculations, floor joist designated DJ5 is apparently designed for a 20 psf live load, since it is part of the corridor floor system please clarify why is it designed for roof live load and not the corridor live load of 100 psf. 2. Geotech report has not addressed footing drainage issue even though it talks in detail about constructing drainage methods for ensuring proper disposal of surface drainage. Foundations also seems to be also not designed for any hydrostatic pressure as a result of ground water pressure. Please have your geotech engineer address the foundation drainage issue whether it is required or not and whether it is a structural design consideration or not based on site specific evaluation? 3. A value of 0.35 is recommended by the geotech engineer for coefficient of friction value for the structural design purposes, seems like a higher value (0.5+) is used. Please verify/ explain how this higher value is consistent with the recommended design value. 4. Page 179 of the calculations shows a footing failing in uplift, how is this resolved? 5. Please address why wind uplift forces were not considered in the canopy connections design? BUILDING REVIEW COMMENTS: Denied 1. Sheet T1.0: The fire sprinkler notes indicate that the sprinkler system is in compliance with NFPA 13 and 45. NFPA 45 is for fire protection of laboratories. It's assumed this is typographical error. Correct this reference. 2. Sheet T1.0: The fire sprinkler notes indicate a reference to NFPA 45. This standard is for fire protection for laboratories. Provide clarification or remove reference. 3. Sheet T2.0: The sprinkler system is indicated as a NFPA 13R system however, on the previous sheet, it's indicated that a NFPA 13 system is being used. Provide clarification as to what system is being used and correlate all applicable requirements. 4. Sheet T2.0: Under the construction requirements table it is indicated that only a 30 minute dwelling unit separation is required, however, with an NFPA 13R system, a 1 hour fire resistance rating would be required between dwelling units. Additionally, the reference for corridors ratings is not correct. The reference provided is for aisles. Provide the correct information on the table. 5. Sheet T2.0: It appears by the elevations that more the 4% of openings are provided. Provide opening percentage calculations for the south wall to ensure compliance with Table 705.8. 6. Sheet T2.0: A one hour rated floor assembly is required, however, the plans indicate that only a 1/2 hour rating is required. While it's noted that a 1 hour rating has been provided, correct the required to rating to the correct requirement. 7. Sheet T3.0: The exit requirements indicate a NPFA 13 system is being used, however, there are several references to a NFPA 13R system. Provide clarification on the type of system being used and correlate all applicable requirements. 8. Sheet A2.0: (ALL FLOORS) The dwelling unit separations are indicated as 1/2 hour ratings. A 1 hour rated separation is required. Provide the correct dwelling unit separation. 9. Sheet A3.0: Provide a ceiling plan for levels 3 and 4. 10. Sheet A8.1: The trash chute is required to be of 2 hour fire resistance rating. The wall tags indicate the rating is less than the requirement. Provide a correct rating for the trash chute in accordance with Section 713.13.1. 11. Sheet A8.1: The trash room is required to be of 1 hour fire resistance rating. The wall tags indicate the rating is less than the requirement. Provide a correct rating for the trash chute in accordance with Section 713.13.3. 12. Sheet A8.1: The trash discharge room is required to be of 2 hour fire resistance rating. The wall tags indicate the rating is less than the requirement. Provide a correct rating for the trash chute in accordance with Section 713.13.4. 13. General: Provide the entire specification manual. MECHANICAL REVIEW COMMENTS: Denied 1. duct that penetrates more than 2 stories shall be protected with a shaft enclosure sheet M1.0 (IMC2018,607.6.1) 2. Ducts penetrating shaft walls shall be protected with fire and smoke dampers sheet M1.0 (IMC2018,607.5.5) 3. All range exhaust duct's in all apartment unit's shall be in a shaft where duct penetrates fire rated floor/roof ceiling assembly sheet M1.0 (IMC2018,607.6.2) 4. Provide return air to corridor's on all floors sheet M1.0 (IMC2018,403.1) 5. All ceiling FCU installed in the fire rated floor/ceiling assembly shall be protected in an approved manner sheet M1.0 (IMC2018,607.6.2) 6. Ceiling diffuser's that penetrate fire rated floor ceiling assembly's shall be protected in an approved manner on all floors sheet M1.0 (IMC2018,607.6.2) 7. Indicate where the trash discharge room is, your only indicating trash rooms, the trash discharge room must be a 2 hour rated room that the trash discharges in sheet M1.0 (IMC2018,106.3.1) & (IBC2018,713.13.4) 8. Provide make up air for the the exhaust in all the trash rooms M1.1 (IMC2018501.4) 9. Mechanical systems shall not be located in an elevator shaft sheet M1.2 (IMC2018,303.8) 10.Provide the VRV Xpress, piping layout with the refrigerant capacity for the condenser unit and the piping refrigerant. sheet M3.0 (IMC2018,106.3.1) ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied First Plumbing Review: 1). Add primary & secondary scupper details to plan page A4.0 or P1.1, -IPC 1106.5, 1108.3 2). Add primary & secondary scupper sizing calculations to plan page A4.0 or P1.1 -IPC 1106.1, 1106.5, 1108 3). Show the secondary scupper location for the small roofs on plan page P1.1 - IPC 1108.3 4). On plan page A6.0 revise note #10 to include primary & secondary roof drain nozzle -IPC 106.3.1 5). community kitchen on plan pages P1.0, P1.2 has a cooking appliance community sink will need to discharge thru an grease interceptor. -IPC 1003.1 6). multiple washers installed installed in this facility will be required to discharge thru a lint interceptor. -IPC 1003.6 ( due to multiple washers doesn't meet exception) 7). Add a total GPM load note to the Building drain/sewer connection on plan page P1..0 8). Plan page P2.3 needs to illustrate the vertical gas location to the DOA-1. -IFGC 106.3.1 9). Hose bibs on plan page P2.0 need shut off valves -IPC 606.2 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 05/18/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 05/25/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | 1. Sheet T1.0: The fire sprinkler notes indicate that the sprinkler system is in compliance with NFPA 13 and 45. NFPA 45 is for fire protection of laboratories. It's assumed this is typographical error. Correct this reference. 2. Sheet T1.0: The fire sprinkler notes indicate a reference to NFPA 45. This standard is for fire protection for laboratories. Provide clarification or remove reference. 3. Sheet T2.0: The sprinkler system is indicated as a NFPA 13R system however, on the previous sheet, it's indicated that a NFPA 13 system is being used. Provide clarification as to what system is being used and correlate all applicable requirements. 4. Sheet T2.0: Under the construction requirements table it is indicated that only a 30 minute dwelling unit separation is required, however, with an NFPA 13R system, a 1 hour fire resistance rating would be required between dwelling units. Additionally, the reference for corridors ratings is not correct. The reference provided is for aisles. Provide the correct information on the table 5. Sheet T3.0: The exit requirements indicate a NPFA 13 system is being used, however, there are several references to a NFPA 13R system. Provide clarification on the type of system being used and correlate all applicable requirements. 6. Sheet A2.0: (ALL FLOORS) The dwelling unit separations are indicated as 1/2 hour ratings. A 1 hour rated separation is required. Provide the correct dwelling unit separation. 7. Sheet A3.0: Provide a ceiling plan for levels 3 and 4. 8. Sheet A8.1: The trash chute is required to be of 2 hour fire resistance rating. The wall tags indicate the rating is less than the requirement. Provide a correct rating for the trash chute in accordance with Section 713.13.1. 9. Sheet A8.1: The trash room is required to be of 1 hour fire resistance rating. The wall tags indicate the rating is less than the requirement. Provide a correct rating for the trash chute in accordance with Section 713.13.3. 10. Sheet A8.1: The trash discharge room is required to be of 2 hour fire resistance rating. The wall tags indicate the rating is less than the requirement. Provide a correct rating for the trash chute in accordance with Section 713.13.4. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@tucsonaz.gov 520-837-7033 Fire Plans Examiner |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/25/2022 | VVERA1 | OUT TO CUSTOMER | Completed |