Permit Number: T22CM03080
Parcel: 116140660

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T22CM03080
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/02/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Approv-Cond Activity Number: T22CM03080


GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Conditionally Approved
1. Fire blocking shall be installed in all walls and concealed spaces including the existing truss roof in areas where the framing is exposed during construction. 2018 IRC R302.11.


BUILDING REVIEW COMMENTS:
Conditionally Approved
1. The window and door note sheet A2 indicates the 2012 IRC, all work shall comply with the 2018 IRC as adopted by the City of Tucson.


MECHANICAL REVIEW COMMENTS:
Conditionally Approved
1. All ducts, air handlers and filter boxes shall be sealed. 2018 IRC M1601.4.1.


ELECTRICAL REVIEW COMMENTS
Approved


PLUMBING REVIEW COMMENTS:
Conditionally Approved
1. All plumbing fixtures will be low flow type. Toilets are to be 1.6 gallons per flush or less, and showerheads and faucets are to not exceed 2.5 gallons a minute. This will be verified in the field on inspection. Ordinance 7178.
2. All plumbing drain, waste and vent systems shall be tested for leaks in accordance with the 2018 IRC P2503.5 prior to concealing.
3. All hot water lines will be insulated to a minimum of R3 2018 IRC N1103.4.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov