07/14/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8” solid core) with self-closing and self-latching provision, R302.5.1.
2. Ducts serving a dwelling may not have openings into the garage, R302.5.2. Remove the extended duct (Toxic gas passage). A garage may have a separate HVAC unit such as a mini split.
3. Show a ½" gypsum board (garage side) on all walls common to the garage and house or other fire rated product in compliance with R302.6. The dwelling side also requires ½" gypsum board for controlling fire spread.
07/15/2022 STEVE SHIELDS ZONING REVIEW Approved