Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM02855
Parcel: 11016216B

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM02855
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/26/2022 STEVE SHIELDS ZONING REVIEW Completed
04/26/2022 IMONSHI1 ENGINEERING REVIEW Completed
04/26/2022 SSHIELD1 NPPO REVIEW Completed
05/09/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Approv-Cond Activity Number: T22CM02855

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Conditionally Approved
1. Fire blocking will be installed in all walls and concealed spaces including the existing areas in which the framing is exposed during construction. 2018 IRC R302.11.


BUILDING REVIEW COMMENTS:
Conditionally Approved
1. The new laundry room is not indicated as having any mechanical heating or cooling installed and therefore is not considered conditioned space as proposed. Note: A minimum of R30 in the ceiling would be required if the laundry room is to be conditioned in the future.


MECHANICAL REVIEW COMMENTS:
Conditionally Approved
No mechanical heating or cooling has been included in this submittal.


ELECTRICAL REVIEW COMMENTS
Conditionally Approved
1. All exterior outlets in wet areas shall be provided with a weatherproof enclosure with “in-use” covers. 2017 NEC 406.8.


PLUMBING REVIEW COMMENTS:
Conditionally Approved
1. All plumbing drain, waste and vent systems shall be tested for leaks in accordance with the 2018 IRC P2503.5 prior to concealing.
2. All hot water lines will be insulated to a minimum of R3 2018 IRC N1103.4.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
05/14/2022 JVINCEN1 FIRE REVIEW Approved