Permit Number: T22CM02824
Parcel: 110050640

Address:
2865 N DESERT AV

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - T22CM02824
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
07/26/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM02824
Guest house
2865 N DESERT AV Zoning R-1

TRANSMITTAL DATE:? July 26, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

These comments are still applicable,

1.COMMENT: Please provide a complete plan set, Since the scope of work has changed and structure is to be a sleeping quarters, A sleeping quarters is subject to wet bar setup including single-bowl sink and under-the-counter fridge. No cooking facilities permitted.


2.COMMENT: Upon further investigation the main dwelling has a total of 3, plus the sleeping has one bedroom and the work shop would be considered a bedroom. Giving a total of 5 bedrooms. “R-1 ZONE, a single family residence is subject to UseSpecific Standards 4.9.7.B.7 which states “ For any new single-family dwelling in the R-1 zone with five bedrooms , three parking spaces are required.For every bedroom over five, one additional space is required for each bedroom . For all single-family dwellings in the R-1 zone with five or more bedrooms , and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom , all parking spaces must be located on-site , either in a side or rear perimeter yard . Parking spaces may not be located in a vehicular use area in any front street perimeter yard . A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.





If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
07/27/2022 NGARCIA3 OUT TO CUSTOMER Completed