Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM02822
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 04/27/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 04/27/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 05/02/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM02822 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Mechanical Drawing M2, Mechanical Roof Plan shows 15 New AC Units on existing roof. These RTU’s weigh 750 or 800 or 1200 pounds. Submit calculations justifying the adequacy of Roof Structural Members to support these RTU’s. 2. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings. BUILDING REVIEW COMMENTS: Denied 1. Sheet C1: The plans indicate that this a business use and this use is a appropriate for a doctor's office. However, it's noted that surgery will be occurring. Provide clarification the type of surgery that will be occurring. It appears that it will meet the requirements of an ambulatory care center. If this is true, please comply with the applicable requirements of Section 422. 2. Sheet C1: The occupant load provided is incomplete. Multiple functions are present. Section 1004.3 states each function must be calculated independently for a total occupant load. The waiting areas have not been included in the occupant load. Include these areas into the occupant load and update applicable requirements as necessary. 3. Sheet A0: The egress plan does not provide exit access travel distances. Provide the exit access travel distances. 4. Sheet A0: Provide all exit signage locations on the egress plan along with tactile exit signage in accordance with Section 1013. 5. Sheet A0: The doors of the H/C restroom in the south hall encroach into the means of egress more than the permitted allowances. Provide a corrected door swing in accordance with Section 1005.7.1 6. Sheet A0: The soiled holding room door encroaches into the means of egress more than the permitted allowances. Provide a corrected door swing in accordance with Section 1005.7.1 7. Sheet A0: The storage closet doors encroach into the means of egress more than the permitted allowances. Provide a corrected door swing in accordance with Section 1005.7.1. 8. Sheet A2: Provide the amounts and types of medical gases being stored. If the amounts exceed the maximum allowable quantities found on Tables 307.1(1) and 307.1(2), then provide evidence of compliance with the applicable requirements of the Section 427.2. 9. Sheet A2: Provide an accessible drinking fountain in accordance with Section 211 of the 2010 ADAAG. 10. Sheet A3: Provide the location of all egress illumination in accordance with Section 1008. 11. General: Provide a typical wall schedule with all related details. 12. Sheet A6: Provide an accessible area for the receptionist desk in accordance with Section 227 of the 2010 ADAAG, MECHANICAL REVIEW COMMENTS: Denied 1. Return air shall be approximately the same as supply air. provide more return air grills sheet M1 (IMC2018,403.1& 601.5 item 4) 2. Provide cfm ratings for all return air grills sheet M1 (IMC2018,106.3.1) 3. Show where this bathroom exhaust duct is terminating sheet M1 (IMC2018,106.3.1) 4. Where equipment or appliances requiring access are located higher than 16' above grade a permanent ladder or a roof hatch shall be installed sheet M2 (IMC2018,306.5) 5. Please see marked up plan in reviewer folder ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied 1)., Add restroom fixture clearances to architectural plan pages. -IPC 404.2, 405.3.1 2). Add drinking fountain(s) mounting height details to architectural pages. each will need to comply with IPC 410.3 3). Add NFPA99 2018 to plan page C1`applicable codes and to plan page P3 note 2 4). Update med gas storage room door schedule info on plan page A11 to include door signage info that complies with NFPA99 5.1.3.1.8, 5.1.3.1.9 5). Add vacuum piping materials to plan page MP1 - NFPA 99 5.1.10.2 6). This system requires 2 vacuum pumps Update Plan pages P3 & P6. -IPC 5.1.3.7.1.1 7). Relief valve Piping discharge locations for med gas systems needs to be illustrated on plan page P3. -NFPA99 5.1.3.3.3.2 8). Where is this facility's Med Gas reserves located? -NFPA99 5.1.3.5.16 9). Floor sink in Mechanical room needs trap seal protection. update plan page P5 fixture schedule. 1002.4.1 10). add water heater detail to plan page P6 - IPC A106.3.1 11). Add the gas sizing tables used for each gas system on plan Page P4. -IFGC 402.4 12). Add rooftop gas appliance connection detail to plan page P6. -IFGC 106.3.1, 404.9, 408.4, 409.5 ,411, 415.1 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 05/10/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 05/24/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | 1. Sheet C1: The plans indicate that this a business use and this use is a appropriate for a doctor's office. However, it's noted that surgery will be occurring. Provide clarification the type of surgery that will be occurring. It appears that it will meet the requirements of an ambulatory care center. If this is true, please comply with the applicable requirements of Section 422. 2. Sheet C1: The occupant load provided is incomplete. Multiple functions are present. Section 1004.3 states each function must be calculated independently for a total occupant load. The waiting areas have not been included in the occupant load. Include these areas into the occupant load and update applicable requirements as necessary. 3. Sheet A0: The egress plan does not provide exit access travel distances. Provide the exit access travel distances. 4. Sheet A0: Provide all exit signage locations on the egress plan along with tactile exit signage in accordance with Section 1013. 5. Sheet A0: The doors of the H/C restroom in the south hall encroach into the means of egress more than the permitted allowances. Provide a corrected door swing in accordance with Section 1005.7.1 6. Sheet A0: The soiled holding room door encroaches into the means of egress more than the permitted allowances. Provide a corrected door swing in accordance with Section 1005.7.1 7. Sheet A0: The storage closet doors encroach into the means of egress more than the permitted allowances. Provide a corrected door swing in accordance with Section 1005.7.1. 8. Sheet A2: Provide the amounts and types of medical gases being stored. If the amounts exceed the maximum allowable quantities found on Tables 307.1(1) and 307.1(2), then provide evidence of compliance with the applicable requirements of the Section 427.2. 9. Sheet A2: Provide an accessible drinking fountain in accordance with Section 211 of the 2010 ADAAG. 10. Sheet A3: Provide the location of all egress illumination in accordance with Section 1008.11. Plans shall show that the owner shall obtain an operational permit from TFD for State Licensed Facility and Compressed Gases Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/24/2022 | VVERA1 | OUT TO CUSTOMER | Completed |