Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM02642
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2022 | DBENOIT1 | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM02642 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied Sheet A101 – Show the ladder incline angle in section 3. 2018 International Residential Code section AQ104.2.2.2 incline. Ladders shall be installed at 70 to 80 degrees from horizontal. Sheet A101 – Provide roof plan. Sheet A101 – Provide loft guard rail detail to show material, connection and spacing. Storage (17 SF) area do not show guard rail. How is this storage space accessed and protected from falling? Sheet A101 – 30”x30” Shower in compliance with 2018 International Residential Code R307.1 is not provided when toilet encroaching in shower space. Provide toilet and shower space required clearance. MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |