Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T22CM02420
Parcel: 115043680

Address:
522 E HELEN ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T22CM02420
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2022 DBENOIT1 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM02420

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Approved

BUILDING REVIEW COMMENTS:
Approved

MECHANICAL REVIEW COMMENTS:
Approved

ELECTRICAL REVIEW COMMENTS
Denied
1. Unresolved. 2018 IRC Section E3901.3.1, E3901.4.1. Clarification needed. Revise plans to clarify the location of the dishwasher and under-counter refrigerator electrical connections. The dishwasher is not permitted to be on the same circuit as the (2) required small appliance branch circuits. If the receptacle outlets shown (to the left of the sink) are installed below the counter for the connection of the appliances, show that correct receptacle outlet spacing has been provided for above the countertop.
2. Unresolved. 2018 IRC Section E3902.9. Revise the plans to show that GFCI protection has been provided in the laundry area (ckt 13) and for the dishwasher. Electrical note #38 indicates GFCI protection is required, but the plans do not indicate how this has been provided for.

PLUMBING REVIEW COMMENTS:
Approved

If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
06/23/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM02420
522 E Helen St -NR-1
Sleeping Quarters Addition (3rd Review)

TRANSMITTAL: June 23, 2022

This site is located in the NR-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. This comment was not addressed. Clearly show and dimension the required vehicle parking spaces on the site. Demonstrate that the dust control requirements under UDC Article 4.9.7.B.7 are clearly met. Based on the provided floor plans and the Definition of a Bedroom, this site shows six (6) bedrooms. Per UDC Article 4.9.7.B.7 this site requires 4 vehicle parking spaces. Clearly show the 4 8’-6” x 18’-0” vehicle parking spaces This comment was not addressed. Provide a floor plan for the existing residence so that it can be determined if the requirements of UDC Article 4.9.7.B.7 are applicable. For your information all four (4) of the rooms shown on the plan are considered a bedroom, see UDC Article 11.4.3 Definition of a Bedroom.

2. This comment was not addressed demonstrate that the requirement of UDC Article 7.4.6.K.2 are met. As primary access to the vehicle parking area, carport, is proposed off of an alley demonstrate on the plan that the requirements of UDC Article 7.4.6.K.2 are met.

COMMENTS: the following comments are relative to an application for NPZ Review (UDC 5.10.3).

This site is located in the NR-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 – 9.

3. This comment was not addressed. NPZ is a separate review & submittal. NPZ Application can be found at: https://www.tucsonaz.gov/files/integrated-planning/Special_Districts_Application_Revised_9-10-21_fillable.pdf, and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using Submission Type “Special Districts”. Prior to zoning approval an NPZ review and approval is required. Owner is proposing to construct an attached four (4) bedroom addition. The property fronts on one local street Helen Street. Structure appears to meet setbacks and is located in the rear yard.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
09/01/2022 NMARTEL1 DESIGN EXAMINER REVIEW Needs Review