Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM02358
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/20/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T22CM02358 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Place the code reference on the plans. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: Provide a site plan showing all buildings, R106.1.1. Show the location of utility lines to the building. FLOOR PLAN: Provide a floor plan showing each proposed room with labeled function and dimensions. Show door locations and window sizes with type identified as XO or SH. Include the identification of adjacent rooms with door or window opening into the proposed space. Exterior walls with a fire separation distance less than 3-foot to the neighboring property line require not less than one-hour fire-resistive construction. Show compliance with R302.1 (City of Tucson Amended) by providing a section detail of materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. Roof projections extending into the 3-foot fire separation distance require not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). The fire protected overhang may not extend closer than 24” from the property line. STRUCTURAL PLAN: Locate and size beams, rafters, and headers for supporting live and dead structural loads, R804 including a ledger attachment to the dwelling. SECTIONS - DETAILS: Show a complete cross-section detail of the new exterior wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. Show exterior wood siding, sheathing and wall framing anchored with ½” x 10” bolts and with pressure treated sill. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground, R317.1 item 5. The framed wall may require a stem for achieving the 6” clearance between framing and ground (R317.1 item 5) or the floor level could be raised a minimum of 6” above grade. ELECTRICAL PLANS: Show code compliant device locations and circuit sizes for any receptacles or lighting with GFCI protection, E3902. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 06/21/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM02358 7262 E 19th St – R-1 Attached Shed TRANSMITTAL: June 21, 2022 This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. The following comments shall be addressed prior to submitting for the DDO: 2. Provide a residential plot plan the meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf: a. The plot plans shall be drawn to an Engineering scale, i.e. 1” = 10” – the plot plan provided is not to scale and the parcel shape does not match the Longview Estates Lot 137 final plat. b. The lot coverage calculation is not correct. c. Provide the height of the proposed walls of the addition. d. Show the location of all utility lines. e. Indicate the zoning of the property and all surrounding properties. f. Provide the legal description, “LONGVIEW ESTATES LOT 137”. As the proposed structure is attached to the main dwelling the neighbors setback waiver is not applicable and a Design Development Option (DDO) must be submitted and approved to reduce the perimeter yard to 1’-0”. As no wall heights were provided Zoning cannot determine the required setbacks. Once the wall heights are provided Zoning will provide the required Zoning comments so that a DDO can be submitted for review. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 06/21/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 06/21/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM02358 7262 E 19th St – R-1 Attached Shed TRANSMITTAL: June 21, 2022 This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. The following comments shall be addressed prior to submitting for the DDO: 2. Provide a residential plot plan the meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf: a. The plot plans shall be drawn to an Engineering scale, i.e. 1” = 10” – the plot plan provided is not to scale and the parcel shape does not match the Longview Estates Lot 137 final plat. b. The lot coverage calculation is not correct. c. Provide the height of the proposed walls of the addition. d. Show the location of all utility lines. e. Indicate the zoning of the property and all surrounding properties. f. Provide the legal description, “LONGVIEW ESTATES LOT 137”. As the proposed structure is attached to the main dwelling the neighbors setback waiver is not applicable and a Design Development Option (DDO) must be submitted and approved to reduce the perimeter yard to 1’-0”. As no wall heights were provided Zoning cannot determine the required setbacks. Once the wall heights are provided Zoning will provide the required Zoning comments so that a DDO can be submitted for review. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 06/24/2022 | AWARNER1 | NPPO | REVIEW | Approved |