Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T22CM02296
Parcel: 131112160

Address:
5710 E 32ND ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T22CM02296
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/08/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits

Provide a wall section for showing the exterior wood siding, sheathing and wall framing with a 6" clearance above the ground, R317.1 item 5 and compliant ceiling insulation placement.

The back porch and ramada require a complete plan set for obtaining a permit.

Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the as-built ramada construction plans with necessary alterations for achieving 20128 IRC code compliance.

The ramada roof may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection. Provide compliance with R302.1 (City of Tucson Amended) by removing the porch roof within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).
08/10/2022 WBERGER1 ZONING REVIEW Reqs Change Provide a neighbor waiver signature for 5709 East 33rd Street. The waiver provided is for 5709 East 32nd Street, which is not a property affected by the ramada setback.

Provide a floor plan of the entire residence demonstrating that five or more bedrooms total are not proposed. Three parking spaces are required in the side and rear yards if five bedrooms total are proposed.