Permit Number: T22CM02296
Parcel: 131112160

Address:
5710 E 32ND ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM02296
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/30/2022 WBERGER1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Wyatt Berger
Planner

PROJECT: T22CM02296
5710 E 32nd Street
Enclose carport to den (1st Review)

TRANSMITTAL DATE: March 30, 2022

COMMENTS: the following comments may be relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to use-specific standards 4.9.7.B.5-.9.

1. For any single-family residence with five bedrooms, three parking spaces are required (UDC 4.9.7.B.7). Provide a floor plan of the entire residence and clarify whether the den is to be used as a bedroom. If five or more bedrooms are proposed, show the location of the three parking spaces on-site.
2. The attached back porch of the residence appears on aerial photography beginning in 2016. Provide permit documentation of this porch or include it within this permit's scope of work.
3. The detached ramada appears on aerial photography beginning in 2014. Provide permit documentation of this ramada or include it within this permit's scope of work.

The detached ramada and detached storage structure do not appear to meet setbacks on the submitted plans. The minimum setbacks are the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

These setback reductions can be dealt with in one of two ways, 1) Process within the required DDO process stated below for the side perimeter yard setbacks or, 2) Secure neighbor setback waivers. To secure these waivers the following text shall be provided on the plot plan and be signed and dated by the property owners of the houses to the south, east, and west. Provide the following text on the plot plan:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If neighbor waivers cannot be secured, a Design Development Option (DDO) must be submitted and approved to reduce the required setbacks,
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type "Zoning Administration". If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
03/30/2022 WBERGER1 NPPO REVIEW Passed
04/19/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide legible notation.

Show exterior wood siding, sheathing and wall framing with a 6" clearance above the ground, R317.1 item 5.
05/19/2022 PCAMARE1 ENGINEERING REVIEW Passed