Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM02251
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/31/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/31/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 03/31/2022 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 04/21/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM02251 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Indicate how the new addition will be tied to the existing house at the foundation/ slab. Provide detail or notes for this connection on the drawings. 2. Indicate the required vertical support under the new 4x8 beam (such as double or triple wall stud) that will sit directly on the new foundation. BUILDING REVIEW COMMENTS: Denied 1. Note on sheet 1 that all work shall be done in accordance with the City of Tucson adopted codes and ordinances. 2. Clarify what work will be done in the existing laundry room and indicate the new use of this room on the drawings. 3. Note on the drawings that fire blocking will be installed in all walls and concealed spaces where newly built or existing areas in which the framing is exposed during construction. 2018 IRC R302.11. MECHANICAL REVIEW COMMENTS: Denied 1. Note on the drawings that all bath fans will be exhausted directly to the exterior. 2018 IRC M1505.2. 2. Note that ducts, air handlers and filter boxes shall be sealed. 2018 IRC M1601.4.1. 3. Note on the drawings that the ducts will be tested for air leakage in accordance with 2018 IECC R4503 unless they are installed within conditioned space. 4. Note on the drawings that the new ductwork will be insulated to a minimum of R8 if not installed within conditioned space. 2018 IECC R403.3 ELECTRICAL REVIEW COMMENTS Denied 1. Indicate the location of the existing electrical service panel on the drawings. 2. Note on the drawings that smoke detectors and carbon monoxide detectors will be installed in the existing dwelling, not just the new bedroom. The location of these detectors will be verified during inspection. 2018 IRC R314.2. 3. Note on the drawings that all smoke detectors shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. 4. Note on the drawings that the smoke alarm devices will receive their primary power from the building wiring with a battery backup. 2018 IRC R314.4.6. 5. Note that all new or replaced 15- and 20-amp outlets shall be tamper proof type. 2017 NEC 210.52. PLUMBING REVIEW COMMENTS: Denied 1. Clarify if the existing water service and water meter is of sufficient size to accept the new plumbing load. 2. Note on the drawings that all plumbing fixtures shall be low flow type. Toilets are required to be low flush using 1.6 gallons per flush or less, while showerheads and faucets must not exceed 2.5 gallons a minute. Ordinance 7178. 3. Indicate a floor drain in the utility room on the drawings. 2018 IRC P2719.1 4. Provide manufactures specifications for the new water heater. 5. Note on the drawings that all plumbing drain, waste and vent systems shall be tested for leaks in accordance with the 2018 IRC P2503.5 prior to concealing. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |