Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM02104
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/30/2022 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet G1; Code Check: Please provide the plumbing fixture calculations per the IBC Table 2902.1 for the required water closets, lavatories, drinking fountain, and service sink. 2. General: Please provide a site plan per the IBC Section 107.2.6. 3. General: Please provide a floor plan indicating the exit access travel distances per the IBC Section 1017. 4. General: Please provide written responses to all review comments. |
03/31/2022 | PAUL CAMARENA | ZONING | REVIEW | Approved | |
03/31/2022 | PCAMARE1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
04/03/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
04/12/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | The use of a point-of-use water dispenser in lieu of a drinking fountain requires the installation of a permanently mounted disposable cup dispenser. The cup dispenser shall be located adjacent to the water dispenser with the dispensing end between 34" and 48" above the finished floor. |
04/12/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
04/12/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
04/18/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
04/28/2022 | IMONSHI1 | ENGINEERING | REVIEW | Passed |