Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T22CM01866
Parcel: 127111050

Address:
6030 E 2ND ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM01866
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/22/2022 IMONSHI1 ZONING REVIEW Reqs Change FROM: Iman Monshizadeh

PDSD Zoning Review Section

PROJECT: T22CM01866 – Bedroom addition

Plot Plan Review (1st Review)

6030 E 2nd St / R-1 Zone

TRANSMITTAL DATE: 03/22/2022



Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.



1.COMMENT: as per 4.9.7.B.7 of the Unified Development Code, Provide a floor plan for the existing residence so that bedroom count for a residence in an R-1 zone can be verified on the next submittal. If bedroom count is 5 or more, 3 parking spaces will be required and will need to be shown on the site plan



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
03/22/2022 IMONSHI1 ENGINEERING REVIEW Passed
03/22/2022 IMONSHI1 NPPO REVIEW Passed
04/06/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Show a complete cross-section detail of the new exterior wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. Show exterior wood siding, sheathing and wall framing anchored with ½” x 10” bolts and with pressure treated sill. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground, R317.1 item 5.

2. Interior alterations require the installation of smoke alarms at existing bedrooms, R314.2.2. Provide notation if the smoke alarms are existing or proposed.

3. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6.

4. Show a circuit or gas line for operating the water heater.