Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM01860
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/14/2022 | VFLORES1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | PLEASE CONTACT PC ADDRESSING UNIT NUMBER NEEDS TO BE ASSIGNED PRIOR TO ISSUANCE PH# 520-724-9512 EMAIL: ADDRESSING@PIMA.GOV |
| 03/24/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM01860 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Sheet A102: The accessible routes through the space seem to below the minimum required width. Please indicate clearly the accessible routes throughout the space. 2. Sheet A102: The equipment in the service counter area and kitchen seem to impeded beyond the maximum allowances. Provide a clear circulation path in accordance with Section 1003.3.3 and 1003.6. 3. Sheet A102: Provide a dimensioned equipment floor plan to ensure compliance with required minimum exit width capacities for seating. Provide evidence of the compliance with Section 1029.13.1. 4. Sheet A103: Additional exit signs are requested adjacent to the open kitchen and dining area that indicate the direction the exits in accordance with Section 1013.1. 5. Raised character and braille exits sings are required at each exit discharge. Provide exit signage in accordance with Section 1013.4. MECHANICAL REVIEW COMMENTS: Denied 1. Sheet M101: Provide evidence of compliance of exhaust outlet separation from mechanical air intakes in accordance with IMC Section 501.3.1. ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied 1. Floor drain #2 is required to be a greases interceptor and drain to the grease line in accordance with Section 1003.3.1. 2. Roof equipment condensate cannot discharge to the grease system. Provide a correct drainage solution for this occurrence in accordance with Section 1003.2. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 03/29/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 03/29/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM01860 3460 S Kino Pkwy – PAD-15 New Food Service (1st Review) TRANSMITTAL: March 29, 2022 This site is located in PAD-15 Food Service is an allowed use in the PAD. 1. Zoning has reviewed the building plans for compliance with DP21-0213 and the following comments need to be addressed. Until DP21-0213 is approved Zoning cannot approve the building plan. 2. The covered patio area does not match what is shown on DP21-0213. Either the DP or building plans will need to be revised to match. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 03/29/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 04/03/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 04/07/2022 | JGARCIA1 | WATER | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/07/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |