Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM01855
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/29/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 03/29/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/29/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 03/30/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM01855 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide Structural Calculations for New 3.5x9 GLB Roof Joists supporting New Mechanical Units. The Calculations submitted only considered roof Dead and Live Loads. Verify if the Joists size is adequate where the RTU’s are present. 2. Provide Structural Calculations for New 8.75x16.5 GLB Roof Girder supporting New Mechanical Units. The Calculations submitted only considered roof Dead and Live Loads. Verify if the Girder size is adequate where the RTU’s are present. 3. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings. BUILDING REVIEW COMMENTS: Denied 1. Cover Sheet: The allowable sq ft. listed is incorrect. Provide a corrected allowable sq ft in accordance with Table 506.2. 2. Sheet CC1.0:Provide a total updated calculated occupant load that includes the areas that are not in scope. 3. Sheet CC1.0:The occupant load for the fixed seating is incorrect. Provide a corrected occupant load along with the calculations in accordance with Section 1004.6. 4. Sheet CC1.0:The occupant load for the juice bar is incorrect. This occupant load factor does not appear on Table 1004.5. The juice bar would be part of the open area. Provide a corrected occupant load. 5. Sheet CC1.0:The exit plan does not indicate the width of exit access components or travel distances. Provide all necessary dimensions and travel distances. 6. Sheet CC1.0: The construction type listed is not a construction type that is recognized by the IBC. Provide a corrected construction type in accordance with Chapter 6. 7. Sheet CC1.0: Show all exit lighting on the exit plan in accordance with Section 1013. 8. Show all existing floor plans. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E4.0: 2 Comments: Panel VIP CB 29, 31 for CU-3 should have a 30-amp CB or smaller to match HVAC Equipment schedule on sheet E2.0. Otherwise upsize fused disconnect and wire on sheet E2.0. General Note #3 is unreadable. PLUMBING REVIEW COMMENTS: Denied First Review: 1). Add Plumbing plans with illustrations, information, specifications, & fixture schedule for the relocated & added restroom fixtures shown on plan pages D1.0 & A1.0. and for all the plumbing related work involved with the added Juice Bars. -IPC A106.3.1 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 03/30/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Denied 1. Cover Sheet: The allowable sq ft. listed is incorrect. Provide a corrected allowable sq ft in accordance with Table 506.2. 2. Sheet CC1.0:Provide a total updated calculated occupant load that includes the areas that are not in scope. 3. Sheet CC1.0:The occupant load for the fixed seating is incorrect. Provide a corrected occupant load along with the calculations in accordance with Section 1004.6. 4. Sheet CC1.0:The occupant load for the juice bar is incorrect. This occupant load factor does not appear on Table 1004.5. The juice bar would be part of the open area. Provide a corrected occupant load. 5. Sheet CC1.0:The exit plan does not indicate the width of exit access components or travel distances. Provide all necessary dimensions and travel distances. 6. Sheet CC1.0: The construction type listed is not a construction type that is recognized by the IBC. Provide a corrected construction type in accordance with Chapter 6. 7. Sheet CC1.0: Show all exit lighting on the exit plan in accordance with Section 1013. 8. Show all existing floor plans. |
| 04/13/2022 | ROBERT SHERRY | WATER | REVIEW | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/14/2022 | VVERA1 | OUT TO CUSTOMER | Completed |