Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM01796
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM01796 Studio Addition (1st Review) 2590 N WOODLAND RD Zoning R-1 TRANSMITTAL DATE: ?March ?22, ?2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENTS: Provide a floor plan for the existing residence on the plan so that Zoning can verify if the requirements of UDC Article 4.9.7.B.7 are applicable to this project. 2.COMMENTS: Please provide a scale on the elevations. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. 3.COMMENTS: The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 22ft the required perimeter yard setback from the proposed addition to the south property line is 14’-9", the proposed setback is 14’-7”. The addition can be moved to meet the required setback or a Design Development Option (DDO) must be submitted and approved to reduce the required setback,DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 03/23/2022 | IMONSHI1 | ENGINEERING | REVIEW | Passed | |
| 03/23/2022 | IMONSHI1 | NPPO | REVIEW | Passed | |
| 04/06/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | The house is 5,045 and would require 2,000 GPM for the addition. The required GPM from the IFC 2018, Table B105.1 cannot be reached due to the hydrants being too far away from the property. You will need to install fire sprinklers in your property and the plans shall show that fire sprinklers are being installed and deferred to TFD. You shall also contact Tucson Water as the fire sprinkler system will require 3/4" meter. If you have any fire questions please contact me: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 04/13/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Completed |