Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM01793
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/19/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM01793 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied - Not Addressed in Resubmittal 1. 2018 IRC Section R317.1(5). Revise drawing A109 with naturally durable wood or pressure-preservative-treated wood for wood siding, sheathing and wall framing on the exterior of a building having a clearance of less than 6 inches from the ground. 2. 2018 IRC Section R317.1(5). Revise drawings with naturally durable wood or pressure-preservative-treated wood for wood siding, sheathing and wall framing on the exterior of a building having a clearance less than 2 inches measured vertically from concrete steps, porch slabs, patio slabs and similar horizontal surfaces exposed to the weather. 3. 2018 IRC Table R802.5.1.(1). Revise drawing A109 with lumber species, grade and spacing used in designing span of new ceiling joist (none shown at this time). BUILDING REVIEW COMMENTS: Denied - Not Addressed in Resubmittal 1. 2018 IRC Section R806. Revise drawings with roof cross ventilation openings including minimum of 1-inch space between the insulation and roof sheathing or provide unvented enclosed rafter framing with air-permeable insulation (R806.5.2 climate zone 2). 2. 2018 IRC (Prescriptive) Table N1102.1.2 (R402.1.2). Revise drawings with ceiling insulation of R-38 with 12 inches of space in depth required for fiberglass insulation between ceiling joist/rafters or provide unvented enclosed rafter framing with air-permeable insulation totaling R-38 (R806.5.2 climate zone 2). MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Denied- Not Addressed in Resubmittal 1. 2018 IRC Section E3901.7 and E3902.3. Revise drawings with not less than one outdoor GFCI receptacle outlet that is readily accessible from grade level at the back of the dwelling unit. 2. 2018 IRC Section E3901.12 and E3902.3. Revise drawings with one outdoor GFCI receptacle outlet located on the same level and within 25 feet of the heating, air-conditioning and refrigeration equipment. 3. 2018 IRC Section E3902.16 and E3902.17. Revise electrical drawing with arc-fault circuit-interrupter protection for branch circuits 120-volt, single-phase, 15- and 20-ampere outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreations rooms, closets, hallways, laundry areas and similar rooms or areas. 4. 2018 IRC Section E4002.14. Tamper resistant receptacles are required in most locations. PLUMBING REVIEW COMMENTS: Conditionally Approved No Plumbing Provided. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 04/20/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved |