Permit Number: T22CM01776
Parcel: 129023850

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM01776
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/21/2022 LSHAMIS1 ZONING REVIEW Approved
03/21/2022 LSHAMIS1 ENGINEERING REVIEW Passed
03/21/2022 LSHAMIS1 NPPO REVIEW Passed
04/04/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T22CM01776
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

An ADU is an independently functioning dwelling and requires an address issued by Pima County.

A new dwelling unit requires collection of development impact fee when the building permit is processed, City of Tucson Ordinance #11203.

GENERAL COMMENTS:

1. Show an electrical circuit or gas line size for supplying the stove/range and any other alterations for adding a kitchen to the originally permitted Sleeping Quarters.

SITE PLAN:

1. Clarify the alterations included for the “Interior Remodel” notation at the existing dwelling. This proposal requires a separate permit for Unit #1 as permits are issued separately for each addressed dwelling.

PLANS:

1. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1.

ELECTRICAL PLANS:

1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location may be coordinated with TEP for approval.