Permit Number: T22CM01657
Parcel: 126180690

Review Status: Active

Review Details: 3RD PARTY REVIEW - RESIDENTIAL

Permit Number - T22CM01657
Review Name: 3RD PARTY REVIEW - RESIDENTIAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
04/25/2022 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW RECEIVED
04/25/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM01657
4164 E Camino De La Colina – R-1
Bedroom Addition (1st Review)

TRANSMITTAL: April 25, 2022
Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.
This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

1. Provide a full floor plan for the entire residence so that Zoning can verify the total number of bedrooms on site and therefore be able to determine if the requirements of UDC Article 4.9.7.B.7 apply. UDC Article 4.9.7.B.7 states “For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.

2. It does not appear that the side street perimeter yard setback shown along Bryant Ave is correct. Provide a dimension from the centerline of Bryant to the face of curb and from the face of curb to the east property line. Per Paving Plan I-589 sheet 10, found at: https://www.tucsonaz.gov/apps/maps-and-records/construction-plans/details/I-589, the distance from centerline of Bryant to the curb is 15’-0” and from curb to the east property line is 15’-0”.

3. Under Zoning Information remove the reference to “PERIMETER YARD INDICATOR AA” from the plan as this has not been applicable since 2011.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.
04/25/2022 ANY 3RD PARTY REVIEW-COMMERCIAL AT 3RD PARTY OFFICE Active
04/26/2022 SSHIELD1 ENGINEERING REVIEW Passed
04/26/2022 SSHIELD1 NPPO REVIEW Passed