Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - 3RD PARTY
Permit Number - T22CM01657
Review Name: PLANS OK TO SUBMIT - 3RD PARTY
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/12/2022 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 04/12/2022 | LOREN MAKUS | ENGINEERING_QA | REVIEW | Passed | |
| 04/25/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM01657 4164 E Camino De La Colina – R-1 Bedroom Addition (1st Review) TRANSMITTAL: April 25, 2022 Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. 1. Provide a full floor plan for the entire residence so that Zoning can verify the total number of bedrooms on site and therefore be able to determine if the requirements of UDC Article 4.9.7.B.7 apply. UDC Article 4.9.7.B.7 states “For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. 2. It does not appear that the side street perimeter yard setback shown along Bryant Ave is correct. Provide a dimension from the centerline of Bryant to the face of curb and from the face of curb to the east property line. Per Paving Plan I-589 sheet 10, found at: https://www.tucsonaz.gov/apps/maps-and-records/construction-plans/details/I-589, the distance from centerline of Bryant to the curb is 15’-0” and from curb to the east property line is 15’-0”. 3. Under Zoning Information remove the reference to “PERIMETER YARD INDICATOR AA” from the plan as this has not been applicable since 2011. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. |
| 04/25/2022 | VFLORES1 | ADA | REVIEW | Passed | |
| 04/25/2022 | VFLORES1 | BUILDING-COMMERCIAL | REVIEW | Passed | |
| 04/25/2022 | STEVE SHIELDS | ZONING_QA | REVIEW | Passed | |
| 04/25/2022 | VFLORES1 | FIRE | REVIEW | Passed | |
| 04/25/2022 | SSHIELD1 | ZONING HC | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/25/2022 | VFLORES1 | OUT TO CUSTOMER | Completed |