Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM01654
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/08/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 03/17/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM01654 Addition (1st Review) 2626 N Gill Zoning R-1 TRANSMITTAL DATE: ?March ?17, ?2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. COMMENT: The storage room would be considered a bedroom for zoning purposes. A bedroom is defined as the following: 1) Any room that is designated as a bedroom; 2) Any enclosed room that has a minimum area of 60 square feet and has an accessible opening to the exterior of the building incompliance with the International Building Code (IBC),whether termed a studio, family room, study, den, bonus room,or any other name, except for a living room, dining room, kitchen , and bathrooms; and 3) Any room designated as a bedroom for the purpose of any other code requirement, see UDC Article 11.4.3 Definitions -B. That all said with the proposed addition this SFR will have 5 bedrooms. COMMENT: Please label and dimension the required parking spaces per UDC Use Specific Standards 4.9.7.B.7 “ For any new single-family dwelling in the R-1 zone with five bedrooms , three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom . For all single-family dwellings in the R-1 zone with five or more bedrooms , and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom , all parking spaces must be located on-site , either in a side or rear perimeter yard . Parking spaces may not be located in a vehicular use area in any front street perimeter yard . A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used." COMMENT: Please provide the height of the structure measured from design grade. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 03/23/2022 | IMONSHI1 | NPPO | REVIEW | Passed | |
| 04/06/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Completed |