Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM01406
Parcel: 124071040

Address:
924 E 9TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM01406
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/07/2022 SBLOOD1 ENGINEERING REVIEW Passed
03/14/2022 STEVE SHIELDS ZONING REVIEW Approved
03/14/2022 SSHIELD1 NPPO REVIEW Passed
03/17/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Show the location of electric lines from property line to building, R106.1.1.

The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. The necessary mast height at the existing panel location may not be a feasible installation.

Tucson Electric Power requires meters and associated equipment to be relocated from under patios when the service is upgraded or the area is enclosed, TEP SR-405.10.L