Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM01406
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/07/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 03/14/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 03/14/2022 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 03/17/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Show the location of electric lines from property line to building, R106.1.1. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. The necessary mast height at the existing panel location may not be a feasible installation. Tucson Electric Power requires meters and associated equipment to be relocated from under patios when the service is upgraded or the area is enclosed, TEP SR-405.10.L |