Permit Number: T22CM01301
Parcel: 136251310

Address:
6632 E MARY DR

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM01301
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/07/2022 SBLOOD1 ENGINEERING REVIEW Passed
03/10/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM01301
6632 E Mary Dr – R-1
Porch Addition (1st Review

TRANSMITTAL: March 10, 2022
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

1. Remove the aerial photo from the plot plan and provide a residential plot plan the meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

2. Provide a perimeter yard setback for the post supporting the proposed porch to the east property line.

All new construction is required to meet current code requirements for perimeter yard setbacks. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

3. Based on a height less than 9’-0” the required perimeter yard setback from the post supporting the proposed porch to the east property line is 6’-0”, proposed is unknown. If less than 6’-0” a Design Development Option (DDO) will need to be submitted and approved to reduce the required perimeter yard setback.

DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.
If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/10/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Clarify the distance between the structure and property line. A roof overhang may not extend closer than 24" to the neighboring property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1.
03/10/2022 SSHIELD1 NPPO REVIEW Passed