Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM00756
Parcel: 10408009F

Address:
4625 N ORACLE RD

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM00756
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/17/2022 ROBERT SHERRY WATER REVIEW Completed
02/25/2022 JPEELDA1 FIRE REVIEW Reqs Change 1. Plans shall show that deferred submittals are: fire sprinkler and fire alarm.
2. Add note: Owner to obtain an operational permit for State Licensed Facilities & Compressed Gases from TFD
3. Provide occupant load and evacuation plan
4. Provide detail of medgas room, including list of gases, sizes of tanks and quantity.

Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
02/28/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM00756

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Approved


BUILDING REVIEW COMMENTS:
Denied
1. The construction type is listed as Type IV, which is heavy timber. No heavy timber is provided. Provide a corrected contrustion type. For the remaining review of this project, it will be assumed that type V-B is desired.
2. Provide existing and demolition plans.
3. Provide a thorough egress plan with all applicable requirements met for compliance in accordance with Chapter 10.
4. The occupant load calculation provided is incorrect. There are spaces other than business uses present that will need to be calculated. (classroom, patient waiting room, conference room) Provide a corrected occupant load in accordance with Table 1004.5.
5. Provide an enlarged floor plans for the proposed restrooms. It appears that there will be clear floor space issues.
6. Based on the egress that will be provided, there will be a dead end corridor in the south dentist office and/or a corridor with encroachment issues in the sterile room issues to access the exit. Provide clarification or a corrected floor plan.
7. Indicate all emergency exit lighting and means of egress illumination of the reflected ceiling plan in accordance with Sections 1013 and 1008.


MECHANICAL REVIEW COMMENTS:
Conditionally Approved
Approved/Subject to field approva


ELECTRICAL REVIEW COMMENTS
Approved


PLUMBING REVIEW COMMENTS:
Denied
1). Provide Demo Plan. -IPC A106.3.1
2). Med gas Tank storage room mechanical Ventilation on plan page M1 needs to comply with -NFPA99 9.3.6.5.3, thru 9.3.6.5.3.7
3). Add a med gas room closet door detail to plan page P6 showing verbiage Label that complies with -NFPA99 15.4.2.2.8
4). Vacuum exhaust detail on plan page P6 shows 2 shut off valves & braided flex connector. Valves can only be installed when multiple pumps are exhausted together NFPA99 5.1.3.7.7.5 & connections need to comply with NFPA99 5.1.3.7.7.6
5). Vacuum exhaust materials on plan page P6 need to comply with NFPA99 5.1.3.7.7.6
6). Provide vacuum pump manufacturer specs, model information. -IPC A106.3.1
7). Revise note on plan pg P6 Vacuum detail " vacuum exhaust to be 25ft from air intake" NFPA99 5.1.3.7.7.2
8). Add Med gas , Med Air, Vacuum labeling information to plans or provide spec manual. -NFPA99 section 5.1.11.1
9). Cold water piping not illustrated to P8 drinking fountain near existing restrooms. -IPC A106.3.1
10). Closed Operating room #1 near dr. office is missing exam sink as shown in all other closed operating rooms? Is this sink required by health dept or other entities that over see these facilities? if yes provide required Plumbing illustrations. -IPC A106.3.1
11). Plan Page P7 piping schedule shows Natural gas piping, Could not locate any natural gas piping throughout plan set? If no gas is work is being done, remove from schedule. -IFGC A106.3.1
12). Add fixture spacing measurements details for dual lavs & urinal to plan pg. A1.2. -IPC 405.3.1
13). Add shower compartment detail to plan page A1.2 -IPC 421.4 thru 421.4.2
14). Add shower pan/base materials to plan page P7 -IPC 421.5
15). Revise Med gas test pressure note on plan pg P7 to 150psi NFPA99 15.4.7.4.4.4
03/03/2022 STEVE SHIELDS ZONING REVIEW Approved
03/03/2022 SSHIELD1 ENGINEERING REVIEW Passed
03/03/2022 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
03/03/2022 VVERA1 OUT TO CUSTOMER Completed