Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM00666
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/23/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM00666 451 W Auto Mall Dr – C-3 Storage Container Addition (2nd Review) TRANSMITTAL: March 23, 2022 This site is located in the C-3 zone (UDC 4.7.22). Medical Service: Outpatient, limited to blood donor centers is a permitted use in this zone (Table 4.8-4) as a S = Permitted as Special Exception Use [1] Mayor and Council Special Exception Procedure, Section 3.4.4 1. This comment has not been addressed. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
03/23/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00666 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Previous comment #2: While it's understood that exit 3 is not a required exit and only the occupants of the storage area would use that exit; all exits provided must be code compliant. Additionally, Sheet A001 clearly indicates the travel distance for individuals off the donor floor to exit 3 and is indicated to be used by those occupants. Provide updated floor plans that do not show exiting through the intervening storage space. 2. The north wall is within 10'-15' of the property line and will require a fire resistance rating of 1 hour. Provide an exterior wall assembly that meets the fire resistance rating in accordance with Table 602. 3. The north wall is within 10'-15' of the property line. The maximum amount exterior wall openings is 45%. Provide evidence of compliance with this requirement in accordance with Table 705.8. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/Subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved 2. E101: RTU#1 needs to upsize conductor feed to #6 AWG as FLA is greater than 40 amps. EOR response: BSC Response: Per Specification Section 26-0519 – Low Voltage Electrical Power Conductors and Cables, insulation types TW and UF are not called out to be used. Reviewer: It is not the conductor, it is the lug/termination rating per NEC 110.14(C) which requires you to also use the 60 degree column for temperature/conductor application. If the lugs/terminations are known to be 75 degree rated, you do not have to upsize. PLUMBING REVIEW COMMENTS: Denied Second Review: 1). SAME-Plan Page A343 shows roof drain detail, Plan page A141 needs to show roof drain locations. Pages need to correlate. IPC A106.3.1 **Per ONYX response building only has gutter & downspouts**- Remove roof drain detail if not used -IPC A106.3.1 2). OK -Plumbing pages need to illustrate above ground roof drain piping with sizing & GPM loads. -IPC 1106.2, A106.3.1 **DOWNSPOUTS** 3). SAME-Plan page A343 shows overflow scupper with downspout detail, plan page A141 needs to show overflow locations. plan pages need to correlate.**Per ONYX response building only has gutter & downspouts** -IPC A106.3.1 Remove scupper detail 4). SAME- Plan page A343 overflow scupper detail needs to include sizes & calculations. -IPC 1106.5, 1108.3-Remove scupper detail if not used 5). SAME-Plan page P110 & P111 shows an Overflow downspout detail connecting below grade, the secondary roof overflow drain needs to discharge above grade -IPC 1108.2.**Per ONYX response building only has gutter & downspouts** Remove underground storm continuation P110 & Downspout detail P111 if not used 6). SAME-Restroom #135 on plan page A153 toilet side wall to center measurement needs to comply with -IPC 405.3.1 7). SAME-Plan Page A153 needs to include lavatory side wall & center to center clearance measurements. -IPC 405.3.1 8). OK 9). Add gutter detail & sizing calculations to plan page P111 -IPC 1106.6 If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
04/05/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | See zoning comments Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
04/08/2022 | DBENOIT1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
04/08/2022 | DBENOIT1 | APPROVAL SHELF | Completed |
04/08/2022 | DBENOIT1 | OUT TO CUSTOMER | Completed |
04/08/2022 | DBENOIT1 | REJECT SHELF | Completed |