Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T22CM00640
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/16/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00640 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. 2018 IRC Section R310. Revise drawings with emergency escape and rescue opening net clear dimension of window when fully open for new sleeping room (3rd bedroom). 2. 2018 IRC Section 314.2, R314.3 and R314.4. Revise electrical drawing with smoke detectors that are to be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual dwelling unit. 3. 2018 IRC Section 315.2 and R315.3. Revise drawings with location of carbon monoxide alarm outside of the bedroom (s) when the dwelling unit includes a fuel-fired appliance and/or has an attached garage. MECHANICAL REVIEW COMMENTS: Denied 1. 2018 IRC Section M1501.1 and M1504.3. Revise plans with every mechanical exhaust system discharge to the outdoors and not into an attic, soffit, ridge vent or crawl space (bath exhaust and clothes dryer). 2. 2018 IRC Section M1502.3. Revise plans with clothes dryer exhaust termination on the outside of the building and not less than 3 feet from any openings. 3. 2018 IRC Section M1502.4.1 and M1502.4.2. Revise plans with clothes dryer exhaust duct details including type of metal, thickness and joints cannot have screws or fasteners that protrude more than 1/8 inch into the inside of duct. ELECTRICAL REVIEW COMMENTS Denied 1. 2018 IRC Section E3902.16 and E3902.17. Revise electrical drawing with arc-fault circuit-interrupter protection for branch circuits 120-volt, single-phase, 15- and 20-ampere outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sun[1]rooms, recreations rooms, closets, hallways, laundry areas and similar rooms or areas. PLUMBING REVIEW COMMENTS: Conditionally Approved 1. 2018 IRC Amend Section P2601.2.1(2). All gray water systems shall be designed and operated according to the provisions of the applicable permit authorized by ADEQ under the Arizona Administrative Code, Title 18, Chapter 9. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/16/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |