Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM00519
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/27/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: PDSD Zoning Review PROJECT: T22CM00519 5401 E Presidio Rd – R-1 Bedroom Addition (1st Review) TRANSMITTAL DATE: January 27, 2022 COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). This site is located in the HR-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. All perimeter yard setbacks are met, Historic review is required for exterior work. Historic review is required and must be approved prior to approval of this building plan. Historic application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf, and is a separate submittal from the building plans submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using Submission Type “Historic Review”. 2. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. 3. The perimeter yard setback requirements shown along the north, east and west property lines are not correct and should be shown as 6’-0” or 2/3 (H) Height of the proposed exterior building wall, greater of the two. 4. Provide the zoning for all adjacent parcels. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
| 01/27/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 01/27/2022 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 02/17/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00519 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Denied Need mechanical drawings and scope of work showing any new ducts, equipment, and bathroom exhaust fans venting to the exterior. ELECTRICAL REVIEW COMMENTS Denied Receptacle spacing requirements of Section E3901.2 are not met. Missing an exterior light at the exterior door - E3903.3 PLUMBING REVIEW COMMENTS: Approved |