Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM00383
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/27/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
02/02/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00383 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Sheet TS1:The construction type listed is not a recognized construction type. It is listed as A.5. Provide a corrected construction type and correlate any applicable requirements. 2. Provide exiting hardware for the fence gate as it is part of the egress system. Section 1010.2. 3. At least 5% of the seating is required to be accessible and be dispersed among all seating types , including the bar area, in accordance with Section 226.1 2010 ADAAG MECHANICAL REVIEW COMMENTS: Denied 1. Please provide a COMcheck that indicates compliance for new mechanical system and scan that data onto one of the mechanical sheets. This provides evidence the mechanical system is in compliance. ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Denied 1. Provide all gas load calculations. 2. No plumbing details provided. Provide all applicable plumbing details. |
02/09/2022 | IMONSHI1 | ENGINEERING | REVIEW | Passed | |
02/09/2022 | IMONSHI1 | ZONING | REVIEW | Approved | |
02/09/2022 | IMONSHI1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
03/02/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | REVIEW COMMENTS: Denied 1. Sheet TS1:The construction type listed is not a recognized construction type. It is listed as A.5. Provide a corrected construction type and correlate any applicable requirements. 2. Provide exiting hardware for the fence gate as it is part of the egress system. Section 1010.2. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/02/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |