Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM00361
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/20/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM00361 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide all special inspection information along with the statement of special inspections in compliance with Chapter 17. BUILDING REVIEW COMMENTS: Denied 1. Provide a new thorough egress plan. 2. Provide clarification on the separation between the business portion and the residential portion of the building. Provide evidence of compliance in accordance with Section 508. 3. The occupant load is calculated incorrectly. There are many spaces in the residential portion that are not accounted for within the calculation. Section 1004.3 and Table 1004.5 4. Depending on the separation required in regards with comment #2, door #108 is required to comply with Section 716 and Table 716.1(2). MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Approved |
| 01/27/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 02/08/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 02/09/2022 | IMONSHI1 | ZONING | REVIEW | Approved | |
| 02/09/2022 | IMONSHI1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 03/02/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | REVIEW COMMENTS: Denied 1. Provide a new thorough egress plan. 2. Provide clarification on the separation between the business portion and the residential portion of the building. Provide evidence of compliance in accordance with Section 508. 3. The occupant load is calculated incorrectly. There are many spaces in the residential portion that are not accounted for within the calculation. Section 1004.3 and Table 1004.5 4. Depending on the separation required in regards with comment #2, door #108 is required to comply with Section 716 and Table 716.1(2). 5. Sheet G1 shows that the occupancy type is a R-1 and it is actually a R-4 and or a I-2 Condition 1 please clarify. 6. Provide detail showing that the separation from B and others meets the requirements of 716 IBC, 2018 7. Fire alarm shall show as a deferred submittal to TFD 8. Owner to obtain a State Licensed Facility operational permit from TFD Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/02/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |