Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM00326
Parcel: 128114170

Address:
4917 E 12TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM00326
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/20/2022 SBLOOD1 ENGINEERING REVIEW Passed
01/27/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM00326
4917 E 12th St. - R-1
Detached Shed Addition. (1st Review)

TRANSMITTAL: January 27, 2022

This site is located in the R-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. The proposed shed does not meet the minimum required perimeter yard setbacks to the north and east property line, see UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 Zone, Res Use to Res Zone the required perimeter yard setback is 6’-0” or 2/3 (H) height of the proposed exterior wall, greater of the two, as measured from design grade to the highest point of the wall. Based on a wall height of 12’-4” the required perimeter yard setback from the proposed shed to the north property line is 8’-3” proposes setback is 0’-0”, based on a wall height of 8’-6” the required perimeter yard setback from the proposed shed to the east property line is 6’-0” proposes setback is 0’-0”. Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________
If the neighbor waiver(s) cannot be secured a Design Development Option (DDO) will need to be submitted and approved to reduce the required setback,
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

2. The two (2) existing sheds shown on the plan do not appear to have been approved as either a compliance review or a permit. Provide the wall heights for both sheds so that setback requirements can be verified. The 192 sq. ft. shed does not meet perimeter yard setbacks to the east property line and will at a minimum required a neighbor’s setback waiver.

3. The lot coverage calculation is not correct. Per UDC Article 6.4.3.B.3.b all vehicle use areas, whether improved or unimproved, are included, see the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

4. Provide the zoning for all adjacent parcels.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
02/08/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Show the shed wall detail with one-hour fire-resistive wall construction parallel with the neighboring property line in compliance with IBC Table 721.1(2) or show a clear 3’ fire separation distance between the property line and the structure including the roof overhang.