Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM00296
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/21/2022 | AWARNER1 | NPPO | REVIEW | Passed | |
| 01/21/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 01/27/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM00296 500 S Convent Ave – HO-3 Rear Porch (1st Review) TRANSMITTAL: January 27, 2022 COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). This site is located in the HO-3 zone (UDC 4.7.15). A single-family residence is a permitted use in this zone (Table 4.8-3). Historic review can waive required perimeter yard setbacks. Historic review is required and must be approved prior to approval of this building plan. Historic application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf, and is a separate submittal from the building plans submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using Submission Type “Historic Review”. The minimum setback is the greater of ten (10) feet, or three-quarters (3/4) the height of the structure’s wall facing each interior property line (Table 6.3-3.A). 1. Required perimeter yard setback from the proposed porch to the north & south property line is 10’-0”, proposed setback was not provided. Per UDC Article 6.4.5.B.2 the setback for a porch type structure is measured from the vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure. 2. Based on the provided plan it appears that you are proposing an encroachment into the neighbors yard to the north. Some type of recorded easement or agreement is required for this encroachment. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov. |
| 02/08/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Show ledger anchor size and spacing for deck to foundation, R507.9. A special inspection request is required with the permit plans for epoxy sets and field welding, R109.2. |