Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM00197
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/07/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
| 03/11/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM00197 10081 E 22nd Street - RX-2 Shade Structure w/solar (2nd Review) TRANSMITTAL: March 11, 2022 This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-1). See Use-Specific Standards 4.9.7.6. The following comments were not addressed. 1. The property shape and dimensions do not match Pima County Assessor’s maps. Provide approved documents that show the parcel in this configuration. 2. Currently it appears that this site is made up of two (2) parcels, 133-39-043F & 133-39-043H and it appears that the structure with the solar is on a parcel by itself. Per UDC Article 6.6.2.B An accessory building shall be built only on a lot occupied by a principal building or use. A Board of Adjustment for Variance will need to submitted and approved to allow a detached accessory structure on the parcel by itself. 3. If the parcels were combined per UDC Article 6.6.3.B Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. A Board of Adjustment for Variance will need to submitted and approved to allow a detached accessory structure in the front yard. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submittal from this building plan and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. Contact of the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. 4. There appears to have been a land split on this property that was not processed through PDSD. Provide approved land split documents with your next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |