01/19/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM00103
1811 S Carthage Pl – Rx-2
Convert Carport to Garage and Extend Garage (1st Review)

TRANSMITTAL: January 19, 2022

This site is located in the RX-2 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3).

As you are proposing to eliminate the required 20’-0” perimeter yard setback to the northeast property line a Board of Adjustment for Variance will be required to be submitted and approved prior to approval of this plan. If you could leave at least 1’-0” between the proposed expansion and the northeast property line a Design Development Option (DDO) could be used. The DDO is a simpler process and is less expansion.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. The Board of Adjustment is a separate submittal from this building plan and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. Contact of the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov.

DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

1. The minimum setback is twenty feet (20) facing each interior property line (Table 6.3-1.A). Proposed perimeter yard setback from the proposed garage to the northeast property line is 0’-0”.
Additional Comments
2. Based on current aerial photos there is some type of detached accessory structure located near the rear corner of the existing shed. Show this structure on the plan.


If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.
01/19/2022 SSHIELD1 ENGINEERING REVIEW Passed
01/19/2022 SSHIELD1 NPPO REVIEW Passed
02/16/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM00103


GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Approved


BUILDING REVIEW COMMENTS:
Denied
1. 2018 IRC Amend Section R302.1. Projections shall not extend to a point closer than 2 feet (610 mm) from the line used to determine the fire separation distance. Projections extending into the fire separation distance shall have not less than one-hour fire-resistive construction on the underside. Revise drawing with extended masonry wall above roof rafters or provide one-hour fire-resistive construction roof within 2 feet of property line.

2. Provide structural analysis of existing CMU wall for roof load


MECHANICAL REVIEW COMMENTS:
N/A


ELECTRICAL REVIEW COMMENTS
Approved


PLUMBING REVIEW COMMENTS:
N/A